CH

Temperature and humidity transmitterASD-WS2000

Transmitter comes with a switch output, can be set alarm output (need to be customized). Non-explosion-proof transmitter. The transmitter uses ABUS mode to communicate with the controller and can be used simultaneously with our products such as gas detectors. The transmitter power supply and bus parts are designed in non-polarity mode and the bus adopts anti-interference and anti-static protection circuit design to ensure the stable operation of the transmitter.

Product Certification

Technical parameters

Temperature measuring range and measuring accuracyHumidity measuring range and measuring accuracy
(-40 ~ 85)℃ ±0.5(℃)(0~100)%RH ±3%RH
Temperature resolution and humidity resolutionOperating voltage and power consumption
0.1(℃) 0.1%(RH)DC24V±6V ≤1.5W
Electrical interfaceResponse time


M4 Pressing screw


<30S(T90)
Communication method and communication distancespecification
TBUS Two-wire bus ABUS Four-bus communication
≤1000m(1.5mm² )
ABS Plastic ≤150g 108×95×45
Output capacityDetection range
30V,2A(Maximum contact current)10-20m² / only
Output mode
A set of passive switching output
(Default does not have this function, if necessary, please contact the manufacturer to customize)

System architecture

ENVIRONMENT

GASES