Carbon monoxide gas detector in underground garageASD5330

The detector has a full temperature compensation function to automatically correct the influence of temperature change on the detection concentration. The bus adopts anti-interference and anti-static protection circuit to ensure long-term stable operation of the detector. The detector adopts high-precision electrochemical gas sensor with high sensitivity and strong anti-interference. Audible and visual alarm signal can be issued when the detector alarms. It can be optional with one linkage output node, which can be equipped with DC12V pulse gas solenoid valve or one dry node output.

Product Certification

Technical parameters

Detection principle Detection range and sampling method
Electrochemical (CO) infrared detection type (CO2) Carbon monoxide, carbon dioxide diffusion type
Working voltage and power Installation mode
DC24V±6V
≤1.5W Normal monitoring
≤3 W Alarm state
Wall-mounted
Suspended ceiling installation
Response time and recovery time Operating temperature and humidity
≤30 秒 -10℃~+55℃ ≤93%RH
Detection range Alarm mode
0 ~ 500PPm(CO) 0 ~ 5000PPm(CO2) Audible and visual alarm
Alarm output Ambient pressure
One set of DC12V pulse solenoid valve is available
Output (1000μf capacitor discharge)
or a set of passive relay outputs
86KPa ~ 106KPa
Specification
ABS Plastic ≤150g 108×95×45