CH

Point flammable gas detector for industrial and commercial useGTYQ-ASD5382

The detector is also compatible with catalytic, infrared, semiconductor, electrochemical and other gas sensors. The shell is made of thickened explosion-proof aluminum alloy shell to ensure long-term stable work in various industrial explosion-proof environments. All-in-one detector can switch 2/3/4 wire system, RS485 and LORA communication by replacing the plug-in module. The detector comes with one switch output (passive relay output), the output can be adjusted by parameter setting to set the following mode, and the detector comes with one sound and light alarm (24DC) drive output.

Product Certification

Technical parameters

Operating voltage and power consumptionDetection range
DC24V±6V ≤1.5W(DC24V)Diffuse type
Electrical interfaceExplosion-proof mark and protection grade



G3/4"Thread (inside)




Ex db IIC T6 Gb :Ex db IIIC T80℃ Db IP66


Alarm valueOperating temperature and humidity
See nameplate for specific parameters of different sensors-40℃~+70℃ ≤93%RH
Detection principleCommunication distance
Catalytic combustion type, electrochemical type, infrared type, PID type≤1000m(RVSP1.5mm² )
Output capacityCommunication mode and operation mode
1 set of passive switching output 220VAC/24VDC,2A
1 set of active sound and light alarm output;
Infrared remote control, distance ≤8 meters
4 ~ 20mA Three-wire communication、
ABUS Four-bus system
TBUS Two-bus system、
RS485、LORA Communication
Display modePressure range and response time
3 Indicator status86KPa~106KPa
<30S(T90)

System architecture

ENVIRONMENT

GASES