Industrial and commercial use point combustible gas detector/toxic and hazardous gas detection (alarm) instrumentGTYQ-ASD5380(Supports a full range of sensors)

The detector is also compatible with catalytic, infrared, semiconductor, electrochemical and other gas sensors. The thickened explosion-proof aluminum alloy shell is designed to ensure stable work in various industrial explosion-proof environments. All-in-one detector can switch 2/3/4 wire system, RS485 and LORA communication by replacing the plug-in module. The special infrared remote control is used to operate, the software is driven by multi-threaded embedded system and programmed by intelligent human-computer dialogue interface, which can meet the various functional requirements of gas detection.

Product Certification

Technical parameters

Operating voltage and power consumption Detection range
DC24V±6V ≤1.5W(DC24V) Diffuse type
Electrical interface Explosion-proof mark and protection grade



G3/4"Thread (inside)




Ex db IIC T6 Gb :Ex db IIIC T80℃ Db IP66


Alarm value Operating temperature and humidity
See nameplate for specific parameters of different sensors -40℃~+70℃(Combustible)-20℃~+40℃ ≤93%RH
Detection principle Communication distance
Catalytic combustion type, electrochemical type, infrared type, PID type ≤1000m(RVSP1.5mm² )
Output capacity Communication mode and operation mode
1 set of passive switching output 220VAC/24VDC,2A
1 set of active sound and light alarm output;
Infrared remote control, distance ≤8 meters
4 ~ 20mA Three wire communication,
ABUS four bus system
TBUS Two-bus system、
RS485、LORA Communication
Display mode Pressure range and response time
2.1 inch high light color LED display
4-digit 8-segment numbers + graphic display
86KPa~106KPa
<30S(T90)

System architecture

ENVIRONMENT

GASES